广东省建筑设计研究院 广东.广州 510000
摘要:大跨度钢梁-混凝土组合楼盖体系跨度往往较大,结构体系偏柔,在满足承载力和变形的同时,有必要进行舒适度分析,本文采用MIDAS/GEN软件对实际工程进行分析,考察了结构的竖向自振频率,并对最不利振动点输入人行激励时程,通过分析其加速度峰值对结构楼板舒适度进行判断。
关键词:大跨度钢梁-混凝土组合楼盖 竖向自振频率 最不利振动点 人行激励 舒适度
Analysis of Comfortableness of large-span steel-concrete composite floor
Li Lun
(Architectural Design & Research Institute of Guangdong Province,Guangzhou 500010,China)
Abstract:The large-span steel-concrete composite floor system is often long and the structural system is flexible,while satisfying the bearing capacity and deformation,it is necessary to carry out comfort analysis.This paper uses MIDAS/GEN software to analyze the actual project,inspects the vertical natural frequency of the structure,then inputs pedestrian excitation to the most disadvantageous vibration point.Through the analysis of the peak vertical acceleration,the floor comfortableness is judged..
Keywords:the large-span steel-concrete composite floor;vertical natural frequency;the most disadvantageous vibration point;floor comfortableness.
0 引言
随着建筑功能要求日益多样化,大跨钢梁-混凝土楼盖、人行天桥及连廊等越来越多,人们对舒适度要求也越来越高,此类结构承载力和变形往往能够满足规范要求,但是刚度偏柔,导致结构自振频率可能位于人行频率的范围内,行人活动会激励结构共振,并由此引起舒适度的问题。因此,有必要对人行激励作用下结构的振动响应进行研究。
1 评价标准
《混凝土结构设计规范》[1]GB50010-2010规定:对大跨度混凝土楼盖结构,宜进行竖向自振频率验算,其自振频率不宜低于下列要求:住宅和公寓 5Hz、办公楼和旅馆4Hz、大跨度公共建筑3Hz,工业建筑及有特殊要求的建筑根据使用功能提出要求。
《高层建筑混凝土结构技术规程》[2]JGJ 3-2010 规定:楼盖结构的竖向振动频率不宜小于3Hz,竖向振动加速度峰值不应超过表3的限值
4 结论
通过对大跨度钢梁-混凝土组合楼盖竖向模态分析,确定了楼板竖向振动最不利点大概位置,并对最不利点施加不同频率的人行激励荷载,分析结果表明楼板竖向振动舒适度能够满足规范要求。
参考文献
[1]GB50010-2010混凝土结构设计规范[S].北京:中国建筑工业出版社,2016.
[2]JGJ 3-2010高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2010.
[3]MATSUMOTO Y.,NISHIOKA T.,SHIOJIRI H.and MATSUZAKI K.Dynamic design of footbridges[C].IABSE Proceedings.1978:1-15.
论文作者:李伦
论文发表刊物:《建筑学研究前沿》2018年第30期
论文发表时间:2019/1/11
标签:楼盖论文; 钢梁论文; 结构论文; 频率论文; 混凝土论文; 舒适度论文; 组合论文; 《建筑学研究前沿》2018年第30期论文;